The filtrating device intends for clearing of technological gases of is high-disperse aerosol particles, including the gases applied in the microelectronic and biological industries.
Notes.
Regeneration of a filtrating device is possible.
Manufacturing of the filtrating tubes consisting of 1-7 filtrating devices, joined by argono-arc welding is possible.
Designation at the order: the Element filtrating eK7.062.715-02
Technical datas
Parametres of filtrated gas: | |
temperature of inertial gases, °C | no more 700 |
temperature oxygen-containing of gases, °C | no more 200 |
Peak difference of pressures | 9 atm. (129 psi) |
degree of clearing, % (for particles in the size more than 0,1 mcm) | not less 99,999 |
Applied materials | electrolytic powders on the basis of nickel |
The area of a filtrating surface, sm2 | 100 |